SCHAFFNER NSG5001A 600V Surge Pulse Source Module
SOLD OUT sold
gen346




Pulse 1,2,6
NSG 5001 Test Pulse Mode;
1 simulates inductive load switch off;
2 simulators spikes caused by ignition turn off;
6 simulators pulse from disconnect of ignition coil when current flowing.

Specification(ISO DP7637/1 12V)
Amplitude Vs:up to 600V(0-100@1,2 0-300@6),
Impedance Ri:4-10ohm@1,2 10-30ohm@6(10ohm@1,2 30ohm@6)
Risetime Tf:1-3us@1,2 60us@6(1us@1,2 <60us@6),
Pulse width Td;50-2000us@1,2 300us@6
(2ms@1 50us@2 300us@6),
Repetition time T1:0.15-15s@1,2,6(0.5-5s@1,2 15s@6),
Delay time T3:<=100us@1,6(<=100us@1,6),
Battery off time T2:200ms@1,2,6(200ms@1,2),
Pulse mode:Single/continuous,
Pulse preselection:1-9999pulses,
Time preselection:1s-9h59m59s,

It requires NSG500 mainframe.