Tektronix

CSA8000B Communication Signal Analyzer main Frame

495,000円(税込)

カテゴリ
オシロスコープ(Oscilloscope)
在庫数
1stock
管理コード
com225
仕様
Self Test Trigger Error

Vertical Systems;
Rise Time/Bandwidth – Determined by the sampling
modules used.
Vertical Resolution – 14 bits over the sampling
modules’ dynamic range.
Horizontal System;
Main and Magnification View Time bases – 1 ps/div
to 5 ms/div in 1-2-5 sequence or 1 ps increments.
Time Interval Accuracy –
Horizontal sensitivity <21 ps: 1 ps + 1% of interval.
Horizontal sensitivity ≥21 ps:
8 ps + 0.1% of interval (short-term optimized mode).
8 ps + 0.01% of interval (locked to 10 MHz mode).
Horizontal Deskew Range: –500 ps to +100 ns on any
individual channel in 1 ps increments.
Record Length – 20, 50, 100, 500, 1,000, 2,000,
4,000 samples.
Magnification Views – In addition to the main timebase,
the CSA8000 supports two magnification views.
These
Horizontal System
Main and Magnification View Timebases – 1 ps/div
to 5 ms/div in 1-2-5 sequence or 1 ps increments.
Time Interval Accuracy –
Horizontal sensitivity <21 ps: 1 ps + 1% of interval.
Horizontal sensitivity ≥21 ps:
8 ps + 0.1% of interval (short-term optimized mode).
8 ps + 0.01% of interval (locked to 10 MHz mode).
Horizontal Deskew Range: –500 ps to +100 ns on any
individual channel in 1 ps increments.
Record Length – 20, 50, 100, 500, 1,000, 2,000,
4,000 samples.
Trigger Sources –
External direct trigger.
External pre-scaled trigger.
Internal clock trigger: Internally connected to
direct trigger.
Clock recovery triggers (from optical sampling modules)
– internally connected to pre-scaled trigger.
Trigger Sensitivity –
External direct trigger output:
50 mV, DC –4 GHz (typical).
100 mV, DC –3 GHz (guaranteed).
Pre-selected trigger input:
800 mV, 2 to 3 GHz (guaranteed).
600 mV, 3 to 10 GHz (guaranteed).
1000 mV, 10 to 12, 5 GHz (typical).
Math/Measurement;
Measurement Set;
Amplitude Measurements: High, Low, Amplitude, Max,
Mid, Min, Peak-to-peak, + Overshoot, – Overshoot,
Mean, Cycle Mean, RMS, Cycle RMS, AC RMS, Gain.
Timing Measurements: Rise, Fall, Period, Frequency,
+ Cross, – Cross, + Width, – Width, + Duty
Cycle, – Duty Cycle, Burst Width, Delay, Phase.
Area Measurements: Area, Cycle Area.
Eye Pattern/Optical Measurements: Extinction Ratio
(Ratio, %, dB), Eye Width, Eye Height, Crossing %, Duty
Cycle Distortion, Jitter (p-p, RMS), Noise (p-p, RMS),
Q-Factor, SNR, Average Optical Power.
Cursors – Dot, vertical bar and horizontal bar cursors.
Waveform Processing;
Up to eight math waveforms can be defined and
displayed using the following math functions: Add,
Subtract, Multiply, Divide, Average, Differentiate,
Exponentiate, Integrate, Natural Log, Log, Magnitude,
Min, Max, Square Root and Filter.
In addition, measurement values can be utilized as
scalars in math waveform definitions.

Power Requirements:Line Voltage 90-132Vrms or 180-250V
Dimention:457(W)-343(H)-419(D),20.8kg,

Maker Price:JPY2,660,000-

付属品